Chinese Journal of Endocrinology and Metabolism ; (12): 934-938, 2019.
Article in Chinese | WPRIM | ID: wpr-800752

ABSTRACT

Objective@#To evaluate the consistency of different methods for detecting aldosterone concentration in blood and to establish a reference interval of serum aldosterone concentration by liquid chromatography-tandem mass spectrometry(LC-MS/MS).@*Methods@#Concentrations of blood aldosterone were measured by LC-MS/MS, chemiluminescent assays (Diasorin, Domestic A and B systems) and radioimmunoassay (RIA) in 138 healthy adults, 67 patients with essential hypertension and 23 patients with primary aldosteronism.@*Results@#Aldosterone concentrations measured by various methods were quiet different(P<0.01). Spearman correlation analysis showed that the correlation coefficient were 0.776(P<0.01) between CLIA (Diasorin) and LC-MS/MS, 0.805(P<0.01) between CLIA (Domestic A) and LC-MS/MS, 0.058(P>0.05) between CLIA(Domestic B) and LC-MS/MS, 0.338(P<0.01) as well as between RIA and LC-MS/MS. Bland-Altman analysis for the measurements showed poor consistency among methods for aldosterone concentrations. The reference interval was 15.2-222.2 pg/ml for serum aldosterone concentrations by LC-MS/MS.@*Conclusions@#There are significant differences of blood aldosterone concentrations determined by different methods. Clinically, a specified reference interval might be needed while using different methods.

2.
Chinese Journal of Endocrine Surgery ; (6): 413-418, 2019.
Article in Chinese | WPRIM | ID: wpr-789234

ABSTRACT

Objective To compare the imported (Diasorin,Italy) and domestic (Mindray,Shenzhen) chemiluminescent systems used in the measurement of plasma aldosterone and renin concentrations;To establish the reference interval of plasma aldosterone and renin concentrations in healthy adults.Methods With the assay instrument and its kits from Italy Diasorin as the reference system,the concentrations of plasma aldosterone and renin were measured by the two systems,in 143 healthy adults,72 patients with hypertension (16 patients with primary aldosteronism) and to establish the medical reference range (P2.5-P97.5) of them.Results The plasma aldosterone (r=0.914,P<0.01) and renin(r=0.977,P<0.01)concentrations detected by the two systems were positively correlated.Distribution of plasma aldosterone and renin was skewed in healthy adults.The reference interval was 30.8-344.6 pg/ml for aldosterone and 2.4-90.0 μIU/ml for renin by the imported chemiluminescent system.The reference interval was 29.4-473.3 pg/ml for aldosterone and 3.6-98.3 μIU/ml for renin by the domestic chemiluminescent detection system.Conclusion The two systems are closely correlated in measuring plasma aldosterone and renin concentrations.

SELECTION OF CITATIONS
SEARCH DETAIL